Aim and Set-Up

Aim: to investigate how the intensity of gamma radiation is reduced (absorbed) as it passes through increasing thicknesses of lead.

Apparatus

  • A sealed gamma source, for example cobalt-60, in a holder on a stand. Handled only with long tongs.
  • A Geiger–Müller (GM) tube connected to a counter (or ratemeter), with a stopwatch if the counter has no timer.
  • A set of lead sheets of different thicknesses, and a micrometer to measure each thickness.
  • Clamps and stands, and a metre rule to set the distances.

edx-i-cp15-setup.png

Following the diagram

  1. The sealed γ source (left) points its beam (green arrow) at the GM tube.
  2. The lead sheets stand in the beam between the source and the tube. Their total thickness is x.
  3. The GM tube gives a pulse for each ionising photon that enters it. The counter adds up the pulses.
  4. The blue arrow shows that the distance from source to GM tube is kept fixed. This is the control variable.
  5. The blue box: add the lead sheets one at a time and record the count for each thickness x.
  6. The key point box: measure the background count first and subtract it from every reading.

💡 Getting rid of beta

Some gamma sources also emit beta particles. A few mm of aluminium in front of the source (kept there for every reading) absorbs any beta, so only gamma reaches the lead.

Method and Results

Method

  1. Before the source is taken out, record the count for 10 minutes with no source present. Work out the background count rate.
  2. Set the source and GM tube a fixed distance apart (for example 10 cm) and clamp them.
  3. With no lead, record the count for a fixed time (for example 2 minutes). Repeat twice more and find the mean count rate.
  4. Measure the thickness of each lead sheet in several places with a micrometer and find the mean.
  5. Add lead sheets one at a time, recording the count rate three times for each total thickness x, up to about 30 mm.
  6. Subtract the background count rate from every mean to get the corrected count rate C.

Typical results

Background count rate = 30 min⁻¹.

x / mmmean measured rate / min⁻¹corrected rate C / min⁻¹ln (C / min⁻¹)
04293995.99
53353055.72
102492195.39
151991695.13
201531234.81
25126964.56
3099694.23

The corrected count rate falls by about the same fraction for every extra 5 mm of lead. This is the sign of an exponential decrease, just like radioactive decay.

The equation behind the graph

The count rate is proportional to the intensity of the gamma beam. For absorption by lead:

C=C0e−μxln⁡C=ln⁡C0−μx\boxed{C = C_0 e^{-\mu x}} \qquad \boxed{\ln C = \ln C_0 - \mu x}

  • CC = corrected count rate through thickness x, in min⁻¹ (or s⁻¹)
  • C0C_0 = corrected count rate with no lead, in the same unit
  • μ\mu = absorption (attenuation) coefficient of lead, in mm⁻¹ (or m⁻¹)
  • xx = thickness of lead, in mm (or m)

The second form is y = c + mx, with y = ln C and x = thickness. So a graph of ln C against x should be a straight line.

ℹ️ A method, not a spec equation

Unlock the full note: start 7 days free. Start free trial

All notes in Nuclear Decay

  1. Binding Energy and Mass Deficit: Using ΔE = c²Δm and the Atomic Mass Unit
  2. Binding Energy per Nucleon: Why Fission and Fusion Release Energy
  3. Alpha, Beta and Gamma: Their Properties and Background Radiation
  4. Writing and Balancing Nuclear Decay Equations
  5. Core Practical 15: How Lead Absorbs Gamma Radiation
  6. Radioactive Decay Is Random: Activity A = λN and the Decay Constant
  7. Half-Life and Exponential Decay: N = N₀e^(−λt) and ln Graphs

What's inside for this topic

9 teacher notes, 249 practice questions, 45 flashcards, 11 quizzes.

Get the full notes, every practice question, flashcards, quizzes and mock papers.

Start your free 7-day trial

Questions? Chat with us on WhatsApp · Try one live lesson

Previous note: Writing and Balancing Nuclear Decay Equations Next note: Radioactive Decay Is Random: Activity A = λN and the Decay Constant

All Edexcel IAL Physics topics · A Level Physics