Calibration, Zero Errors and Parallax | Edexcel IAL Physics notes

Free preview: Calibration, Zero Errors and Parallax

Checking Before You Measure

Calibration

  • An instrument is calibrated when its readings agree with known, correct values.
  • You can check calibration by measuring something you already know: a thermometer in melting ice should read 0 °C, and in boiling water about 100 °C.
  • The simplest check of all is the zero: with nothing to measure, the instrument should read zero.

zero-error.png

Zero Errors

Following the diagram

  • Panel A: with the jaws closed, the micrometer reads +0.03 mm instead of 0.00 mm. Every reading it gives will be 0.03 mm too big.
  • Panel B: with no current, the ammeter needle rests at 0.3 A. Every reading will be 0.3 A too big.

correct value=reading−zero error\boxed{\text{correct value} = \text{reading} - \text{zero error}}

  • A zero error can be positive or negative. If the micrometer read −0.02 mm when closed, you would add 0.02 mm to each reading.
  • A zero error shifts every reading by the same amount, so it is a systematic error. Repeating the reading does not remove it.

📝 Exam hint

A common question: 'State one check the student should make before using the micrometer.' Answer: 'close the jaws and check the reading is zero (check for zero error)'.

Parallax Error

parallax-error.png

  • The pointer (or the top of a liquid, or a spring's end) is a little in front of the scale.
  • If your eye is above or below it, your line of sight crosses the scale at the wrong mark.
  • Only with your eye level with the pointer, looking straight at the scale (at 90°), do you read the right value.

💡 Tip

Ways to reduce parallax: put your eye level with the mark; move the ruler as close as possible to the object; use a set square to line up the object with the scale; use a fiducial marker; or use a digital instrument.

ℹ️ Remember these 4

  1. Calibrate: check against known values.
  2. Zero check before you start.
  3. Correct value = reading − zero error.
  4. Eye level, at 90° to the scale.

Worked Examples

💡 WORKED EXAMPLE 1

Question:

A micrometer reads −0.02 mm when closed. A wire then reads 0.45 mm. Find the true diameter.

Answer:

0.45 − (−0.02) = 0.47 mm

💡 WORKED EXAMPLE 2

Question:

A newtonmeter shows 0.2 N with nothing hanging from it. A load gives a reading of 3.6 N. What is the true weight of the load?

Unlock the full note: start 7 days free. Start free trial

All notes in Practical Skills in Physics I

  1. Planning an Experiment: Variables, Apparatus and a Fair Test
  2. Measuring Instruments: Range, Resolution and Choosing the Right One
  3. Reading Vernier Calipers
  4. Reading a Micrometer Screw Gauge
  5. Calibration, Zero Errors and Parallax
  6. Random and Systematic Errors, Accuracy and Precision
  7. Repeat Readings, Mean Values and Anomalous Results
  8. Number of Readings, Range of Values and Significant Figures
  9. Health and Safety in Physics Practicals
  10. Plotting a Good Graph: Axes, Scales and Lines of Best Fit
  11. Gradients, Intercepts and Straight-Line Graphs (y = mx + c)
  12. Uncertainty and Percentage Uncertainty in Measurements
  13. Improving an Experiment: Reducing Errors and Better Techniques
  14. Physics in Context: Benefits, Risks and Implications
  15. Practical Skills Across the Eight Core Practicals

What's inside for this topic

17 teacher notes, 393 practice questions, 54 flashcards, 12 quizzes.

Get the full notes, every practice question, flashcards, quizzes and mock papers.

Start your free 7-day trial

Questions? Chat with us on WhatsApp · Try one live lesson

Previous note: Reading a Micrometer Screw Gauge Next note: Random and Systematic Errors, Accuracy and Precision

All Edexcel IAL Physics topics · A Level Physics